Ultra Series overview
Explore the Fluke Ultra Series
An introduction to the Ti300U, Ti401U and Ti480U handheld thermal imagers.
Fluke Australia video
The Fluke Ti300U, Ti401U and Ti480U share the same rugged handheld platform, UltraFocus focusing technology and interchangeable lens options. The principal differences are infrared resolution, thermal sensitivity and temperature range: choose the Ti300U for dependable everyday electrical, mechanical, HVAC and building inspections, the Ti401U when smaller or more distant targets demand greater image detail, or the Ti480U for subtle temperature differences, high-temperature applications and the most demanding industrial diagnostics.
Tick Add to compare under each product | Open Compare in the bottom-right corner | Check your selection, and press Compare | On the comparison table, select Highlight differences to quickly see where specifications differ
Fluke Ti300U vs Ti401U vs Ti480U: which should you choose?
The Fluke Ti300U, Ti401U and Ti480U share the same rugged handheld platform, UltraFocus focusing technology, 25° × 19° standard field of view, IR-Fusion imaging, interchangeable lens options and SmartView IR analysis software.
The principal differences are infrared resolution, thermal sensitivity and temperature range. Choose the 384 × 288 Ti300U for dependable everyday inspections, the 640 × 480 Ti401U when smaller or more distant targets require greater detail, or the Ti480U for 50 mK sensitivity, SuperResolution images up to 1280 × 960 and high-temperature measurements up to 1200°C.
| Fluke Ti300U | Fluke Ti401U | Fluke Ti480U | |
|---|---|---|---|
| Infrared resolution |
384 × 288 110,592 pixels |
640 × 480 307,200 pixels |
640 × 480 307,200 pixels |
| SuperResolution | No | No | Up to 1280 × 960 |
| Thermal sensitivity (NETD) | 75 mK (0.075°C) | 75 mK (0.075°C) | 50 mK (0.05°C) |
| Temperature range | −20°C to 650°C | −20°C to 650°C | −20°C to 1200°C |
| Spatial resolution | 1.14 mrad | 0.68 mrad | 0.68 mrad |
| Maximum digital zoom | 4× | 10× | 10× |
| Radiometric video | Yes | No | Yes |
| Best suited to | Routine professional inspections where dependable detail and value are the priorities | Smaller or more distant targets where extra pixels improve identification and reporting | Subtle temperature differences, high-temperature processes and advanced diagnostics |
| Typical inspection work | Electrical panels, HVAC systems, motors, pumps and general building inspections | Switchgear, production equipment, utilities and detailed preventive maintenance | Process equipment, furnaces, complex machinery, R&D and critical asset monitoring |
See Fluke cameras in detail
Watch official Fluke videos covering the TiX and Ultra Series, from camera operation and measurement setup to Super Resolution use of Fluke's analysis software - SmartView IR
Ultra Series overview
An introduction to the Ti300U, Ti401U and Ti480U handheld thermal imagers.
Fluke Australia video
TiX and Ti480 overview
See Fluke’s overview of the TiX580 and the earlier Ti480 infrared camera.
Fluke Corporation video
Ti480U features
Explore the Ti480U in Fluke Australia’s overview of this Ultra Series model.
Fluke Australia video
Ti480U in use
Hear an HVACR technician’s perspective on using the Ti480U in the field.
Fluke Australia video
Focusing technology
Watch a demonstration of LaserSharp focusing on a compatible Fluke thermal camera.
TEquipment video
SmartView reporting
See how Fluke SmartView Research supports thermal analysis, report creation and data export.
TEquipment video
SmartView streaming
Watch how SmartView Research receives and displays live infrared camera data for analysis.
TEquipment video
Choose the Fluke Ti300U for everyday inspections and radiometric video
The Fluke Ti300U provides 384 × 288 native infrared resolution across the same 25° × 19° field of view as the two higher-resolution models. It is the most cost-effective Ultra Series choice for routine professional thermography, while retaining fully radiometric video recording for investigations where temperature changes need to be reviewed over time.
Choose the Fluke Ti300U for:
Choose the Fluke Ti401U for greater component-level detail
The Ti401U increases native infrared resolution to 640 × 480, placing nearly 2.8 times as many detector pixels across the same scene as the Ti300U. Its finer 0.68 mrad spatial resolution makes smaller components easier to distinguish and provides greater flexibility when inspecting from farther away or cropping images for reports.
Its thermal sensitivity and −20 °C to 650 °C measurement range are the same as the Ti300U. The reason to choose the Ti401U is therefore greater spatial detail, rather than improved temperature sensitivity or a wider measurement range.
Choose the Fluke Ti401U for:
Important: the Ti401U does not offer thermal or visible-light video recording. Choose the Ti300U or Ti480U if fully radiometric video is required.
Choose the Fluke Ti480U for subtle differences and high-temperature work
The Ti480U combines the Ti401U’s 640 × 480 native resolution with improved 50 mK thermal sensitivity, 1280 × 960 SuperResolution, fully radiometric video recording and an extended measurement range reaching 1200 °C.
It is the strongest Ultra Series model for demanding investigations where fine thermal contrast, high process temperatures or recorded temperature changes could materially affect the diagnosis.
Choose the Fluke Ti480U for:
All three cameras use a 25° × 19° standard lens (and have the same lens variants available), so they capture approximately the same area when used from the same position.
The difference is how much thermal information is recorded within that view:
The Ti401U and Ti480U therefore place nearly 2.8 times as many measurement pixels across the target. This can make individual connections, components and thermal patterns easier to distinguish, particularly at longer working distances.
The Ti300U and Ti401U have a specified thermal sensitivity of 75 mK, while the Ti480U improves this to 50 mK.
The Ti480U can distinguish finer temperature differences, producing smoother thermal patterns and clearer separation between areas with similar temperatures. This is most valuable when investigating subtle heat transfer, early-stage faults, insulation performance or complex machinery - not simply when locating an obvious hot connection.
All three Ultra Series cameras accept interchangeable lenses that are automatically recognised by the camera:
Choose the lens according to the smallest target you must measure and the distance from which you can safely inspect it. Digital zoom enlarges the displayed image but does not replace the measurement detail gained from the appropriate optical lens.
Fluke Ultra Series FAQ
Clear answers to the most common questions about choosing between the Fluke Ti300U, Ti401U and Ti480U.
The Ti300U provides 384 × 288 native infrared resolution for routine professional inspections. The Ti401U increases this to 640 × 480 for smaller or more distant targets. The Ti480U retains the 640 × 480 detector while adding improved 50 mK sensitivity, 1280 × 960 SuperResolution, fully radiometric video and an extended temperature range up to 1200 °C.
Yes. Both have a native infrared resolution of 640 × 480 and a spatial resolution of 0.68 mrad with the standard lens. The Ti480U differentiates itself through improved thermal sensitivity, SuperResolution, radiometric video capability and its higher maximum measurement temperature.
The Ti300U is a capable choice for regular inspection of panels, breakers, connections and general plant equipment at close to moderate distances. Choose the Ti401U when smaller components, greater working distances or more detailed reports justify the additional resolution. Choose the Ti480U when subtle temperature differences or critical assets demand the greatest diagnostic capability.
The Ti401U and Ti480U provide the most native detail, with 640 × 480 resolution and 0.68 mrad spatial resolution. For genuinely distant targets, combine either model with the appropriate 2× or 4× telephoto lens rather than relying on digital zoom alone.
The Ti300U and Ti480U record fully radiometric thermal video that can be analysed after capture. The Ti401U is designed for radiometric still-image inspection and does not record thermal or visible-light video.
Choose the Ti480U when your work benefits from detecting finer temperature differences, creating 1280 × 960 SuperResolution images, recording radiometric video or measuring targets above 650 °C. If your priority is detailed still-image inspection within a −20 °C to 650 °C range, the Ti401U may provide everything required without paying for capabilities you will not use.
Tell us your application, target size and working distance. We’ll help confirm the most suitable camera and lens configuration.